Pseudomonas CN Agar

Pseudomonas CN Agar is a selective medium used for the enumeration of Pseudomonas aeruginosa in drinking water, bottled water and swimming pool water by membrane filtration. Cetrimide and nalidixic acid (CN) suppress accompanying flora, while the 60 mm plate fits 47 mm membrane filters under ISO 16266.

Special pricing in line with technical specifications is offered for institutional and hospital purchases.

Technical specifications

Type Selective and differential
Use Membrane filtration enumeration of Pseudomonas aeruginosa in drinking, bottled and pool water
Standard ISO 16266
Incubation 36 ± 2 °C, 44 ± 4 h
Typical appearance Blue-green (pyocyanin-producing) colonies; fluorescent or reddish-brown colonies require confirmation
Form Ready-to-use Petri plate
Plate diameter 60 mm
Packaging Specified in the quote

About the product

Pseudomonas CN Agar is a selective and differential medium for enumerating Pseudomonas aeruginosa in water by membrane filtration. Cetrimide and nalidixic acid (CN) suppress Gram-positive bacteria and most accompanying Gram-negative flora. ISO 16266 specifies this medium in 60 mm plates with 47 mm membranes for drinking water, bottled water and swimming pool water.

This product comes as ready-to-use agar plates in 60 mm Petri dishes; after reaching room temperature the plates can be inoculated directly.

Key features

  • Type: Selective and differential medium
  • Selectivity: Cetrimide and nalidixic acid (CN) suppress most accompanying water flora
  • Differentiation: Supports pyocyanin (blue-green) and fluorescent pigment formation
  • Standard: ISO 16266
  • Incubation: 36 ± 2 °C, 44 ± 4 h
  • Form: Ready-to-use Petri plate, 60 mm (suitable for 47 mm membrane filtration)

Applications

  • Enumeration of P. aeruginosa in drinking water networks and domestic water supplies
  • Microbiological control of bottled mineral water and spring water
  • Hygiene monitoring of swimming pools, spas and recreational waters

How to use

  • Collect the water sample aseptically; a sterile sample bag or suitable sterile bottle supports transport.
  • Filter the prescribed water volume through a sterile 47 mm membrane filter.
  • Place the membrane onto the 60 mm Pseudomonas CN Agar surface without trapping air bubbles.
  • Invert and incubate at 36 ± 2 °C for 44 ± 4 h; an interim check at 22 ± 2 h may also be done under ISO 16266.
  • After incubation, examine colonies under daylight and long-wave UV light.

How are results interpreted?

  • Blue-green (pyocyanin) colonies: Accepted directly as confirmed Pseudomonas aeruginosa under ISO 16266; no further confirmation is needed.
  • UV-fluorescent (non-pyocyanin) colonies: Counted as presumptive and confirmed via ammonia production in acetamide broth.
  • Reddish-brown (non-fluorescent) colonies: Counted as presumptive and confirmed with oxidase, acetamide and King's B fluorescence tests.
  • The final count combines directly confirmed blue-green colonies with the confirmed suspect colonies.

Practical tips

  • Store plates at 2–8 °C, inverted and protected from light; bring to room temperature before use.
  • Avoid air pockets beneath the membrane so nutrient diffusion and pigment production remain uniform.
  • Wear suitable eye and skin protection when inspecting plates under UV light.
  • Do not use cracked, dried out or visibly contaminated plates; verify each new batch with known reference strains.

Pseudomonas CN Agar or Cetrimide Agar?

Both select for P. aeruginosa, but their standards differ. For water analysis, ISO 16266 uses Pseudomonas CN Agar with both cetrimide and nalidixic acid. For pharmaceutical and cosmetic testing (European Pharmacopoeia 2.6.13), Cetrimide Agar is used. To run general counts on the same water sample, pair with Yeast Extract Agar; see more under Selective and Differential Media.

Frequently asked questions

Do blue-green colonies on Pseudomonas CN Agar need confirmation?

Under ISO 16266, blue-green pyocyanin-producing colonies are accepted directly as Pseudomonas aeruginosa; only fluorescent (non-pyocyanin) or reddish-brown colonies require confirmation with acetamide, oxidase and King's B fluorescence tests.

Why is a 60 mm Petri plate preferred?

ISO 16266 membrane filtration uses 47 mm filters; a 60 mm plate fits the membrane snugly for full agar contact while saving incubator space.

How do I order Diaplas Pseudomonas CN Agar?

For bulk orders, pack sizes and quotes, contact us on +90 216 473 80 70, via our WhatsApp line or through the quote form; our team will promptly send you the most suitable option and a quote.

Order Form

Choose the product and quantity and leave your contact details; our team will call you right away to confirm your order.

Call us now0216 473 80 70