Cleanroom Installation

Cleanroom Installation

Cleanroom installations planned to ISO 14644-1 and GMP requirements

A cleanroom is an area in which the number of airborne particles is controlled to a defined class, while temperature, humidity and pressure are kept under control. Diaplas supports you from class definition through design, installation and testing.

  • HEPA-filtered HVAC

    Terminal HEPA filters, air change rate and airflow pattern are designed for the target class, together with temperature and humidity control.

  • Pressure cascade

    A pressure difference from cleaner to less clean areas prevents contamination from reaching critical zones; differentials can be monitored continuously.

  • Panel walls, ceilings, epoxy floor

    Non-shedding, easy-to-clean surfaces resistant to disinfectants, with gap-free details at corners and joints.

  • Airlocks and pass-boxes

    Gowning areas, airlocks and material pass-boxes keep transfers between classes under control.

A cleanroom is an enclosed area in which the number of airborne particles is controlled to a defined cleanliness class, and in which temperature, humidity, pressure and airflow are kept under control. It is used to protect a product or process from contamination originating from the air, surfaces and personnel. Diaplas supports cleanroom installation from needs and class definition through design, installation and testing; the scope of the service is defined at the quotation stage according to your needs.

Cleanroom classes: ISO 14644-1 and EU GMP Annex 1

ISO 14644-1 classifies cleanrooms from ISO 1 to ISO 9 according to the number of particles of specified sizes per cubic metre of air; the lower the class number, the cleaner the environment. The classes most often encountered in practice are ISO 5, ISO 7 and ISO 8. For example, the maximum concentration of particles of 0.5 µm and larger per cubic metre is 3,520 for ISO 5, 352,000 for ISO 7 and 3,520,000 for ISO 8.

For sterile medicinal product manufacturing, EU GMP Annex 1 defines areas as grades A, B, C and D. For each grade, particle limits are set for both the at-rest and in-operation states, together with microbiological monitoring limits.

GMP gradeAt restIn operationTypical use
AISO 5ISO 5High-risk operations such as aseptic filling
BISO 5ISO 7Background environment for grade A zones
CISO 7ISO 8Less critical manufacturing steps
DISO 8Not predetermined, set by the facilityLess critical preparation steps

The components of a cleanroom

  • HEPA-filtered HVAC: Air is supplied to the room through terminal HEPA filters. The air change rate and airflow pattern (unidirectional or mixed flow) are calculated for the target class.
  • Pressure cascade: A cleaner area is kept at a higher pressure than the adjacent less clean area. EU GMP Annex 1 gives a minimum of 10 Pa between adjacent rooms of different grades as a guidance value.
  • Temperature and humidity control: Kept within defined ranges for the product, the process and operator comfort.
  • Wall and ceiling panels: Smooth, non-porous, easy-to-clean surfaces resistant to disinfectants; lighting and filters are sealed flush into the panels.
  • Epoxy flooring: Seamless, chemical-resistant, easy-to-clean flooring with coved details at wall junctions.
  • Airlocks and pass-boxes: Allow controlled transfer of people and materials between classes; doors usually operate with an interlock.
  • Gowning area: A transition zone, arranged to suit the class, where cleanroom garments are put on in stages.

Applications

  • Pharmaceutical manufacturing and quality control laboratories
  • Medical device manufacturing and packaging areas
  • Sensitive filling and packaging sections in food production
  • Microbiology laboratories and sterility testing areas
  • Hospital pharmacies and drug compounding units

How do we work?

  1. Needs and class definition: The operations, product risk and applicable regulations are assessed to define the target ISO class or GMP grade for each room.
  2. Design: Layout, personnel and material flow, pressure cascade, air change rate and HVAC concept are planned.
  3. Installation: Components such as the panel system, flooring, HVAC and filtration, airlocks and pass-boxes are installed.
  4. Testing and qualification: Particle counting, HEPA filter integrity (leak) testing, airflow velocity and volume, and room pressure differential measurements are carried out. Qualification is usually documented in DQ (design), IQ (installation), OQ (operational) and PQ (performance) stages.
  5. Periodic monitoring: Particle, pressure differential, temperature, humidity and microbiological monitoring continue at regular intervals.

Consumables for microbiological monitoring

Maintaining a cleanroom's class requires microbiological monitoring as well as particle measurement. Settle plates are used for airborne microorganisms and contact plates for flat surfaces; you can browse suitable culture media for these. Swabs are preferred for sampling irregular surfaces and corners.

For your cleanroom project, contact us or explore our other laboratory solutions.

Questions

Frequently asked questions

What is a cleanroom?

A cleanroom is an area in which the number of airborne particles is controlled to a defined class and in which temperature, humidity, pressure and airflow are kept under control. HEPA-filtered air, a pressure cascade and controlled transfer of people and materials protect the product or process from contamination.

What is the difference between an ISO 14644-1 class and a GMP grade?

ISO 14644-1 classifies areas by the number of airborne particles and is used in many industries. EU GMP Annex 1 applies to sterile medicinal product manufacturing; it defines grades A–D separately for the at-rest and in-operation states and includes microbiological limits in addition to particle limits. For example, grade A corresponds to ISO 5 in both states.

How do I determine which cleanroom class I need?

The class depends on the risk of the operation, whether the product is exposed to the environment and the regulations in your sector. GMP grades apply to sterile medicinal product manufacturing, while ISO classes are the reference for many other applications. During the needs analysis your processes are assessed together and the target class for each room is clarified.

Which tests are carried out after a cleanroom is installed?

Typically particle counting, HEPA filter integrity testing, airflow velocity and volume, room pressure differentials, temperature and humidity measurements. Qualification is documented in DQ, IQ, OQ and PQ stages, and particle and microbiological monitoring continue regularly during use. Which tests are included in your project is defined at the quotation stage.

How do I get a quotation for Cleanroom Installation?

Send us your requirements by phone at +90 216 473 80 70, via our WhatsApp line or through the quote form; our team will clarify the site survey and scope and prepare the most suitable solution and quotation for you.

Let's discuss your cleanroom project

Share your area, process and target class; we will clarify the survey and scope and prepare a suitable cleanroom solution and quotation.

Order Form

Choose the product and quantity and leave your contact details; our team will call you right away to confirm your order.

Call us now0216 473 80 70