Laboratory Setup

Laboratory Solutions
Laboratory Setup: from layout plan to first analysis
Laboratory setup is the integrated planning and implementation of layout, furniture, ventilation, power-water-gas utilities and equipment placement suited to the type of analysis. The scope Diaplas takes on is defined at the quotation stage according to your needs.
Layout and workflow
Separating clean and dirty areas, a one-way flow from sample to report, and planned movement of staff and materials.
Laboratory furniture
Benches resistant to chemicals and disinfectants, storage cabinets and, where needed, fume hood placement.
Ventilation and utilities
Adequate air changes plus power, water, drainage and, where needed, gas lines planned around the laboratory's work.
Biosafety and waste
Positioning of the biosafety cabinet, autoclave and waste handling flow in line with the risk assessment.
Laboratory setup is the design and implementation of all physical conditions of an analytical laboratory, from the layout plan and furniture to ventilation, power, water and gas utilities, equipment placement and waste management, according to the work to be performed. A well-built laboratory protects the sample, the staff and the environment while supporting reliable results and a smooth daily workflow.
Alongside laboratory consumables and culture media, Diaplas also supports laboratories at the setup stage. The scope of the service (planning support, furniture and utilities, equipment supply, or a combination of these) is defined at the quotation stage according to your needs.
Which laboratories?
- Microbiology laboratories: separate areas for media preparation, inoculation, incubation, counting and identification; positioning of the biosafety cabinet and autoclave.
- Quality control laboratories: chemical and microbiological sections planned together for raw material, in-process and finished product testing.
- Food and water testing laboratories: sample receipt, preparation and analysis areas arranged to prevent cross-contamination.
- Clinical laboratories: safe receipt and processing of patient samples and segregation of waste.
Layout and workflow
The core principle of laboratory design is that samples move in one direction from receipt to report, and that clean and dirty areas are kept apart. In a microbiology laboratory, for example, media preparation and sterilisation are separated from inoculation and incubation, and the route taking contaminated material to the autoclave is kept apart from the clean material flow. A typical layout includes:
- Sample receipt and registration
- Sample preparation and homogenisation
- Media preparation, sterilisation and clean storage
- Analysis, incubation and reading areas
- Decontamination, washing and waste exit
Furniture, ventilation and utilities
Benches are chosen from easy-to-clean surfaces resistant to the chemicals, disinfectants and heat in use, and cabinets are allocated by chemical compatibility. Work with volatile chemicals, solvents or acids requires a fume hood; a fume hood must not be confused with a biosafety cabinet, which provides microbiological protection.
- Ventilation: adequate air changes, negative pressure relative to adjacent areas where required, and planned fume hood exhaust.
- Power: circuits planned for equipment loads, earthing, and uninterruptible power for sensitive equipment such as incubators and freezers.
- Water and drainage: hand-wash sinks, eyewash and emergency shower points, analytical water needs and proper disposal of wastewater.
- Gas: gas lines for Bunsen burners or instruments, with the necessary safety measures.
Biosafety levels (BSL-1 and BSL-2)
The biosafety level is determined by the risk group of the microorganisms handled and the risk assessment of the procedures performed. In general terms:
| Level | Typical use | Key requirements |
|---|---|---|
| BSL-1 | Well-characterised microorganisms not known to cause disease in healthy adults; teaching laboratories | Good microbiological practice, hand-wash sink, easy-to-clean surfaces |
| BSL-2 | Agents of moderate hazard; much clinical, food and quality control microbiology | Restricted access, biohazard signage, biosafety cabinet for aerosol-generating procedures, access to an autoclave for waste decontamination |
BSL-3 and higher require directional airflow, controlled entry and additional engineering controls; such projects are assessed separately. The biosafety cabinet should be placed away from doors, busy walkways and supply air diffusers, otherwise its protective air curtain can be disrupted.
Infrastructure for ISO/IEC 17025 accreditation
ISO/IEC 17025 is the international standard specifying general requirements for the competence of testing and calibration laboratories. Its requirements on facilities, environmental conditions and equipment cover providing an environment suitable for laboratory activities, monitoring and recording conditions that can affect results (e.g. temperature, humidity), separating incompatible activities, and managing calibration and maintenance of equipment.
Accreditation is granted to the laboratory by an accreditation body on the basis of its own management system and competent staff; in Türkiye this body is TÜRKAK. A setup does not deliver accreditation on its own, but well-planned infrastructure makes the process easier: traceable temperature records, separated work areas, calibration-friendly equipment placement and controlled access are considered from the start.
How do we work?
- Needs analysis: laboratory type, scope of testing, sample load, staff numbers and target standards are discussed.
- Site survey and design: the existing space is assessed; layout, workflow, furniture and utility needs are defined.
- Quotation: scope, materials and equipment list are clarified and a quote is prepared.
- Installation and handover: furniture, utilities and equipment placement are implemented in the planned sequence.
- Commissioning and consumables supply: equipment is put into operation and culture media and consumable needs are planned for regular supply.
Equipment and consumables
For incubators, autoclaves, biosafety cabinets and other equipment needed with the setup, see our Laboratory Equipment page. For daily needs once the laboratory is running, browse our laboratory consumables, microbiology products and culture media. For controlled environments see Cleanroom Installation, and for an overview the Laboratory Solutions page. To discuss your project, contact us.
Questions
Frequently asked questions
What stages does a laboratory setup cover?
Generally needs analysis, site survey, layout and workflow planning, furniture and utilities (ventilation, power, water, gas), equipment placement, installation and commissioning. The scope Diaplas takes on is defined at the quotation stage according to your project's needs.
Does a microbiology laboratory need BSL-2?
That depends on the risk group of the microorganisms handled and the risk assessment of the procedures. Much food, water and quality control microbiology is carried out under BSL-2 conditions; only teaching laboratories working with well-characterised strains not known to cause disease may be BSL-1. The final decision rests on the laboratory's own risk assessment and applicable regulations.
Does the setup provide ISO/IEC 17025 accreditation?
No. The laboratory obtains accreditation from an accreditation body through its own management system, competent staff and method validation. Well-planned infrastructure makes it easier to meet the standard's facility and equipment requirements, such as monitoring environmental conditions, separating activities and placing equipment so it can be calibrated.
What is the difference between a fume hood and a biosafety cabinet?
A fume hood draws air out of the work area and exhausts it to protect the user from chemical vapours and gases; it does not protect the sample. A biosafety cabinet uses HEPA-filtered airflow to protect the user and the environment, and in Class II cabinets also the sample, against microbiological contamination. One does not replace the other; the need depends on the type of work.
How do I get a quote for Laboratory Setup?
Send us your requirements by phone at +90 216 473 80 70, via our WhatsApp line or through the quote form; our team will clarify the site survey and scope and prepare the most suitable solution and quote for you.
Let's plan your laboratory together
Share your laboratory type, space and scope of testing, and we will define a suitable layout and setup scope together.