Diaplas Neutralizing Solution Swab (10 ml)
10 ml neutralizing rinse solution in a clear tube with an orange screw cap and a white-tipped swab fixed to the cap. For hygiene control and environmental monitoring on disinfected surfaces.
Special pricing in line with technical specifications is offered for institutional and hospital purchases.
Technical specifications
About the product
A neutralizing solution swab is a swab supplied with its own transport tube, designed to collect microbiological samples from disinfected surfaces. The Diaplas Neutralizing Solution Swab consists of 10 ml Neutralizing Rinse Solution in a clear tube with an orange screw cap and a white-tipped swab fixed to the cap. The swab comes out with the cap, the surface is swabbed and the cap is closed again, so the sample travels to the laboratory in the same tube.
Why a neutralizing solution?
Disinfectant left on the surface after cleaning can keep killing the bacteria on the swab tip until it reaches the laboratory, so the result looks cleaner than it is. The neutralizing solution inactivates these residues and helps measure the true microbial load.
Key features
- All in one: Swab, solution and transport tube in one product; no extra diluent needed.
- Swab fixed to the cap: Sampling without touching the swab by hand.
- 10 ml solution: The swab tip is fully immersed in the tube.
- Orange screw cap: Leak-tight transport; samples are easy to recognise.
Where is it used?
- Surface and equipment hygiene control in food production areas
- Cleaning and disinfection verification (after CIP and sanitation)
- Environmental monitoring programmes for Listeria, Salmonella and Enterobacteriaceae
- Surface monitoring in pharmaceutical, cosmetic and laboratory areas
How to use
- Hold the tube upright and unscrew the orange cap; the swab comes out with the cap.
- Press the swab tip against the inner wall of the tube to remove excess liquid.
- Swab a defined area (usually with a 10 × 10 cm template) horizontally, vertically and diagonally while rotating the swab.
- Put the swab back into the tube, close the cap tightly and label the tube.
- Send the sample to the laboratory in the cold chain. There the tube is mixed and the solution is plated on media such as TSA or PCA.
Tips
- Use a new swab for each sampling point.
- Always sample the same area at the same point; results are calculated per area.
- Analyse the sample within 24 hours if possible.
- For dry sampling or your own transport liquid, see the Sterile Swab; all options are in the Swabs category.
- To take a food sample at the same point, use the sterile zip-lock sample bag.
Related guide: How to Perform a Surface Hygiene Swab Test: Sampling with a Neutralizing Swab
Frequently asked questions
What is a neutralizing solution swab used for?
It is used to collect microbiological samples from disinfected surfaces and equipment. Because the solution inactivates disinfectant residues, it gives more reliable results in cleaning verification.
Which medium is a swab sample plated on?
For total viable counts, Tryptic Soy Agar (TSA) or Plate Count Agar (PCA) is usually used. For ready plates see Diaplas Ready-to-Use Petri Dish Medium and our culture media guide.
How do I order the neutralizing solution swab?
For bulk orders, pack quantities and quotes, call +90 216 473 80 70, use our WhatsApp line or the contact page.