Chromogenic Coliform Agar (CCA) is a chromogenic medium for the simultaneous membrane filtration enumeration of Escherichia coli and coliform bacteria in waters with low background flora such as drinking water. Following the colour differentiation defined in ISO 9308-1, it provides clear readings within 21–24 hours on 60 mm plates with 47 mm membranes.

Special pricing in line with technical specifications is offered for institutional and hospital purchases.

Technical specifications

Type Chromogenic
Use Membrane filtration enumeration of E. coli and coliforms in waters with low background flora (drinking water)
Standard ISO 9308-1
Incubation 36 ± 2 °C, 21–24 h
Typical appearance E. coli dark blue-violet; other coliforms pink-red colonies (ISO 9308-1)
Form Ready-to-use Petri plate
Plate diameter 60 mm
Packaging Specified in the quote

About the product

Chromogenic Coliform Agar (CCA) is a chromogenic medium for the simultaneous enumeration of Escherichia coli and coliform bacteria by membrane filtration in waters with low background flora, such as drinking water. Dual chromogenic substrates separate coliform β-galactosidase and E. coli β-glucuronidase activity by colour on one plate. ISO 9308-1 specifies this medium on 60 mm plates with 47 mm membranes as the reference method.

This product comes as ready-to-use agar plates in 60 mm Petri dishes; after reaching room temperature the plates can be inoculated directly.

Key features

  • Type: Chromogenic selective and differential medium
  • Differentiation: Dual chromogenic substrates distinguish E. coli and other coliforms on a single membrane
  • Standard: ISO 9308-1
  • Incubation: 36 ± 2 °C, 21–24 h
  • Form: Ready-to-use Petri plate, 60 mm (suitable for 47 mm membrane filtration)

Applications

  • Enumeration of E. coli and coliforms in drinking water networks and treated water
  • Routine control of bottled water, spring water and disinfected pool water with low background flora
  • Post-disinfection microbiological verification in water treatment plants

How to use

  • Collect the water sample aseptically; a sterile sample bag or sterile bottle simplifies transport.
  • Filter the prescribed sample volume through a sterile 47 mm membrane filter.
  • Place the membrane onto the 60 mm Chromogenic Coliform Agar (CCA) surface without trapping air bubbles.
  • Invert and incubate at 36 ± 2 °C for 21–24 h.
  • Count dark blue-violet colonies as E. coli and confirm pink-red colonies with the oxidase test per ISO 9308-1.

How are results interpreted?

  • Dark blue-violet colonies (E. coli): Both β-galactosidase and β-glucuronidase positive; counted directly as E. coli under ISO 9308-1 and included in total coliforms.
  • Pink-red colonies (presumptive coliforms): β-galactosidase positive only; verified by oxidase testing (oxidase-negative = coliform, ruling out oxidase-positive Aeromonas).
  • Total coliforms: Sum of confirmed oxidase-negative pink-red colonies plus dark blue-violet E. coli colonies.
  • Colourless colonies: Non-coliform bacteria; excluded from the count.

Practical tips

  • Per ISO 9308-1, CCA is intended for waters with low background flora; heavy background flora can overcrowd the membrane.
  • Store plates at 2–8 °C, inverted and protected from light, as chromogenic substrates are light-sensitive.
  • Carry out the oxidase test as prescribed in ISO 9308-1 (typically after subculturing onto non-selective agar).
  • Do not use cracked, dried out, discoloured or contaminated plates; check each new batch with known reference strains.

CCA or Chromogenic E. coli-Coliform Agar (ECC)?

Chromogenic Coliform Agar (CCA) follows ISO 9308-1 for membrane filtration of waters with low background flora. Chromogenic E. coli-Coliform Agar (ECC) is used across both food and water testing in 90 mm and 60 mm formats. Pair with Slanetz & Bartley Agar when also checking for intestinal enterococci, or explore more under Chromogenic Media.

Frequently asked questions

Why is an oxidase test needed for pink-red colonies on CCA?

Some non-coliform bacteria such as Aeromonas also form pink-red colonies; under ISO 9308-1 the oxidase test confirms that only oxidase-negative colonies are counted as coliforms.

Are dark blue-violet colonies also included in the total coliform count?

Yes. Because E. coli is a coliform bacterium, ISO 9308-1 defines total coliforms as the sum of dark blue-violet E. coli colonies and oxidase-negative pink-red colonies.

How do I order Diaplas Chromogenic Coliform Agar (CCA)?

For bulk orders, pack sizes and quotes, contact us on +90 216 473 80 70, via our WhatsApp line or through the quote form; our team will promptly send you the most suitable option and a quote.

Order Form

Choose the product and quantity and leave your contact details; our team will call you right away to confirm your order.

Call us now0216 473 80 70