How to Perform a Total Viable Count: Pour and Spread Plate Methods with PCA

A total viable count (total aerobic mesophilic count) is the basic microbiological analysis that determines the number of microorganisms in a food or sample able to form colonies under aerobic conditions at 30 °C. The reference method is the ISO 4833 series: serial dilutions of the sample are plated with Plate Count Agar (PCA) by the pour plate (ISO 4833-1) or surface plating (ISO 4833-2) technique, incubated at 30 °C for 72 hours, and the result is reported as colony-forming units per gram or millilitre (CFU/g, CFU/ml).

What does a total viable count show?

The count is an indicator used to assess the general microbiological quality of raw materials, production hygiene, the effectiveness of heat treatment and shelf-life trends. It does not show the presence of a specific pathogen: a low total viable count does not mean the product is free of pathogens, which require separate, target-specific methods. In foods that naturally contain high numbers of microorganisms, such as fermented products, the result is not interpreted on its own as a hygiene indicator.

What is Plate Count Agar (PCA)?

PCA is a non-selective medium. An enzymatic digest of casein (tryptone), yeast extract and glucose provide nutrients for a wide range of microorganisms; agar is the gelling agent. Laboratories use it in two forms:

  • Ready-to-use plates: pre-poured PCA plates are used directly for the spread plate method.
  • PCA in bottles: bottled PCA is melted, cooled and poured with the sample into an empty Petri dish for the pour plate method.

In both forms, media performance should be checked according to the principles of ISO 11133.

How is a serial dilution prepared?

The initial suspension is prepared according to the ISO 6887 series; for example, 10 g of sample + 90 ml of diluent gives the 10⁻¹ dilution. Maximum Recovery Diluent (MRD) or saline peptone water are common diluents. At each further step, 1 ml of the previous dilution is added to 9 ml of diluent (10⁻², 10⁻³ …). A new sterile pipette is used at every step and the tube is mixed thoroughly. At least two successive dilutions are chosen, according to the expected load, so that countable plates are obtained.

ISO 4833-1: pour plate method step by step

  1. Transfer 1 ml of each selected dilution into a sterile, empty 90 mm Petri dish.
  2. Pour PCA that has been melted and cooled to 44–47 °C into the dish. The time between dilution and pouring is limited by the standard; do not delay.
  3. Mix the inoculum with the agar by gently swirling the dish on a flat surface and allow it to solidify.
  4. If microorganisms forming spreading colonies are expected, a thin overlay of PCA may be poured onto the solidified surface.
  5. Incubate the dishes inverted at 30 °C for 72 hours under aerobic conditions.
  6. Count the colonies using a colony counter or magnifier; also check the sterility control plates for diluent and medium.

ISO 4833-2: spread plate method

In the spread plate method, 0.1 ml of inoculum is placed on the surface of a pre-poured PCA plate with a dried surface and spread over the whole surface with a sterile Drigalski spreader. Plates are incubated in the same way at 30 °C for 72 hours. Because only 0.1 ml is plated, the detection limit at the same dilution is ten times higher than with the pour plate. As the microorganisms are not exposed to warm agar, the method is advantageous for heat-sensitive flora, and colonies are easier to distinguish on the surface.

Pour plate vs spread plate

FeaturePour plate (ISO 4833-1)Spread plate (ISO 4833-2)
Inoculum volume1 ml0.1 ml
Medium formatPCA melted and cooled to 44–47 °C (bottle)PCA plate with dried surface (ready-to-use plate)
Colony locationWithin and on the agarOn the surface only
Heat exposureInoculum contacts warm agarNone
Incubation30 °C, 72 hours30 °C, 72 hours
Additional equipmentSterile empty Petri dishSterile spreader
Detection limit (from 10⁻¹ dilution)10 CFU/g100 CFU/g

Counting colonies and calculating the result

As a general rule, pour plates containing approximately 10–300 colonies are used for calculation; situations outside this range follow the specific rules of the standard. The result is based on a weighted mean: the total number of colonies on the counted plates is divided by the volume plated and the dilution factor, taking the plates of two successive dilutions into account together so that random deviation from a single plate is reduced.

Worked example

With 1 ml plated and one plate per dilution, 168 colonies are counted at 10⁻² and 15 colonies at 10⁻³. The total is 183 colonies. In the denominator, the plate from the first dilution (1) and the plate from the next, ten-fold more dilute dilution (0.1) together give the factor 1.1: 183 / (1 × 1.1 × 10⁻²) ≈ 16,600. Rounded to two significant figures, the result is reported as 1.7 × 10⁴ CFU/g.

If the pour plate of the 10⁻¹ dilution shows no colonies, the result is reported as "less than 10 CFU/g" (< 10 CFU/g).

Common mistakes

  • Pouring PCA too hot (harms microorganisms) or using agar that has cooled too far and started to set
  • Re-melting bottled medium repeatedly; melted medium is generally used only once
  • Using the same pipette for successive dilution steps
  • Waiting too long between dilution and pouring
  • Not inverting the plates; condensation causes colonies to spread
  • Calculating results from plates outside the countable range

References and standards

  • ISO 4833-1:2013 — Microbiology of the food chain — Horizontal method for the enumeration of microorganisms — Part 1: Colony count at 30 °C by the pour plate technique
  • ISO 4833-2:2013 — Microbiology of the food chain — Horizontal method for the enumeration of microorganisms — Part 2: Colony count at 30 °C by the surface plating technique
  • ISO 6887-1:2017 — Microbiology of the food chain — Preparation of test samples, initial suspension and decimal dilutions for microbiological examination — Part 1: General rules for the preparation of the initial suspension and decimal dilutions
  • ISO 11133:2014 — Microbiology of food, animal feed and water — Preparation, production, storage and performance testing of culture media

Questions

Frequently asked questions

At what temperature and for how long are total viable count plates incubated?

According to ISO 4833-1 and ISO 4833-2, PCA plates are incubated aerobically at 30 °C for 72 hours. Pour plates are placed in the incubator inverted. Results from methods using a different temperature or time should not be compared directly with ISO 4833 results.

How many colonies should a plate have for a total viable count?

As a general rule, pour plates with approximately 10–300 colonies are counted. On overcrowded plates colonies merge and counting becomes unreliable; on plates with very few colonies statistical uncertainty increases. For this reason several successive dilutions are plated according to the expected load.

Should I choose the pour plate or the spread plate method?

For routine food analysis the pour plate (ISO 4833-1) is common because of the 1 ml inoculum and lower detection limit. The spread plate (ISO 4833-2) may be preferred where heat-sensitive flora is expected or colonies need to be distinguished on the surface. With 0.1 ml plated, its detection limit is ten times higher.

How is the result reported if no colonies grow?

The result is not reported as zero but as below the detection limit. For example, if a pour plate inoculated with 1 ml of the 10⁻¹ dilution shows no colonies, the result is "less than 10 CFU/g"; for a plate spread with 0.1 ml of the same dilution it is "less than 100 CFU/g".

How can I obtain PCA plates and bottled PCA from Diaplas?

For ready-to-use PCA plates, bottled PCA, diluent tubes and Petri dishes, call us on +90 216 473 80 70 or fill in the quote form on our website. Stating the product and quantity you need helps us prepare your quote quickly.

Plate Count Agar (PCA) for total viable counts

Browse ready-to-use PCA plates for spread plating, bottled PCA for pour plating and diluent options, and request a quote.

Order Form

Choose the product and quantity and leave your contact details; our team will call you right away to confirm your order.

Call us now0216 473 80 70