Choosing a Petri Dish: 90 mm or 60 mm? A Guide to Sterile Petri Dishes
A Petri dish is a flat, transparent, lidded culture dish used to grow, isolate and count microorganisms on solid culture media. In routine food and water microbiology the most common size is 90 mm; 60 mm dishes are preferred for work that needs less medium and for applications such as membrane filtration.
Petri dish sizes
Petri dishes are named by their nominal diameter. The diameters most often met in laboratories are listed below. Height and exact dimensions vary by manufacturer, so check the product's technical data.
| Diameter | Typical use | Note |
|---|---|---|
| 90 mm | General plating, isolation, colony counts by pour and spread plate, prepared media | Many standard methods are based on dishes of 90–100 mm diameter |
| 60 mm | Membrane filtration, small-volume or costly media, training and trials | Uses less medium; fewer colonies can be counted |
| About 35 mm | Cell culture and very small-volume special applications | Rare in routine food microbiology |
| 140–150 mm | Special applications that need a large surface | Needs more medium and incubator space |
90 mm or 60 mm? How to choose
The method decides. If an ISO method or a laboratory's validated in-house method specifies the dish diameter, use that diameter, because the countable colony range, the amount of medium and the inoculum volume are defined for it.
- 90 mm: The standard choice for pour plate (1 ml inoculum) and spread plate (0.1 ml inoculum) counts. The generally accepted countable range for dishes of this size is about 10–300 colonies. A 90 mm sterile Petri dish is also the most flexible option for isolation and selective media.
- 60 mm: Its surface area is less than half that of a 90 mm dish; with the same inoculum colonies are more crowded and the upper counting limit is reached sooner. A 47 mm membrane filter fits easily inside a 60 mm Petri dish, which is why small dishes are often used in water analysis with a 47 mm membrane filter.
Polystyrene or glass? Sterile single-use Petri dishes
Most routine laboratories today use single-use polystyrene (PS) Petri dishes. Polystyrene is optically clear, so colonies are easy to see and count; dishes are usually supplied sterilised by irradiation in stacked packs. Polystyrene deforms at autoclave temperatures, so it is not re-sterilised for reuse; used dishes are autoclaved as waste and disposed of.
Glass Petri dishes (usually borosilicate) can be washed and re-sterilised by autoclave or dry heat. However, washing, drying and sterilisation add workload, there is a risk of breakage, and detergent left on poorly rinsed dishes can affect microbial growth.
| Property | Polystyrene (single-use) | Glass (reusable) |
|---|---|---|
| Sterility | Supplied sterile, ready to use | Must be sterilised in the lab before each use |
| Autoclave | Not suitable for reuse | Suitable |
| Durability | Light; may crack on impact | Heavy; can break |
| Workload | No washing | Washing, drying and wrapping needed |
| Visibility | High optical clarity | Clear; scratches increase over time |
What do vents do?
Many Petri dish lids have small ribs (vents) that leave a narrow gap between lid and base. This gap eases gas exchange, stops the lid sticking to the base and helps moisture disperse after hot medium is poured. Unvented dishes have a closer-fitting lid and may be preferred to reduce drying of the medium during long incubations. Unless the method calls for a particular type, vented dishes are common for routine aerobic work.
Pouring plates and the pour plate method
Two terms are often confused: pouring plates means preparing plates by pouring molten agar into empty sterile dishes, while the pour plate method is a counting technique in which the sample is placed in the dish first and molten medium is poured over it (ISO 4833-1). For example, Plate Count Agar in bottles is melted and used in this way.
- Melt the bottled medium completely and cool it in a water bath to the temperature specified in the method; medium that is too hot harms microorganisms and increases condensation.
- Write the sample code and date on the base of the dish, not the lid; lids can get mixed up.
- For the pour plate method, place 1 ml of sample or dilution in the centre of the empty dish.
- Lift the lid only as far as needed, pour the medium and close the lid at once.
- Mix gently by swirling the dish in circles on a flat surface; do not spill over the edge.
- Let the medium set on a level surface, then incubate the dishes inverted (lid down).
Inverted incubation stops water droplets that form on the lid from falling onto the agar and spreading colonies. In the spread plate method (ISO 4833-2), 0.1 ml is inoculated onto a plate with a dried surface and spread evenly with a sterile Drigalski spatula. For the full counting workflow, see the total viable count guide.
Storage and handling tips
- Store empty sterile dishes in their unopened packaging in a dry, dust-free place out of direct sunlight.
- Reclose opened packs; do not leave unused dishes collecting dust on an open shelf.
- Do not use packs that are torn, wet or whose sterility information is illegible.
- Do not leave freshly poured dishes in tall stacks; the dishes in the middle cool more slowly and form more condensation.
- Store prepared Petri dish media as the manufacturer recommends, usually refrigerated and inverted; let them reach room temperature before use.
- Autoclave used dishes and dispose of them according to biological waste rules.
References and standards
- ISO 24998:2008 — Plastics laboratory ware — Single-use Petri dishes for microbiological procedures
- ISO 7218 — Microbiology of the food chain — General requirements and guidance for microbiological examinations
- ISO 4833-1:2013 — Microbiology of the food chain — Horizontal method for the enumeration of microorganisms — Part 1: Colony count at 30 °C by the pour plate technique
- ISO 4833-2:2013 — Microbiology of the food chain — Horizontal method for the enumeration of microorganisms — Part 2: Colony count at 30 °C by the surface plating technique
- ISO 11133:2014 — Microbiology of food, animal feed and water — Preparation, production, storage and performance testing of culture media
Questions
Frequently asked questions
What sizes do Petri dishes come in?
The most common diameter is 90 mm, used for general plating, isolation and colony counts. 60 mm dishes suit membrane filtration and small-volume work, dishes of about 35 mm are used for special work such as cell culture, and 140–150 mm dishes for applications that need a large surface. Height and exact dimensions vary by manufacturer.
Why are Petri dishes incubated upside down?
Water droplets can form on the inside of the lid during incubation. If the dish is upright, they fall onto the agar, spread colonies into each other and spoil the count. With the dish inverted (lid down) the droplets stay on the lid, and drying of the medium is also reduced.
Can plastic Petri dishes be autoclaved?
Single-use polystyrene Petri dishes cannot be autoclaved for reuse; they deform at autoclave temperatures. Used plastic dishes are autoclaved only as waste, in a suitable autoclave bag, and then disposed of. If reuse is needed, choose glass Petri dishes.
What are the vents on a Petri dish for?
Small ribs on the inner rim of the lid leave a narrow gap between lid and base. The gap eases gas exchange and stops the lid sticking to the base. Unvented dishes have a closer-fitting lid and may be preferred to reduce drying during long incubations.