How to Take a Food Sample: Correct Sampling with Sterile Bags and Containers
Food sampling means taking a portion that represents the product into a sterile sample bag or container using aseptic technique, labelling it correctly and delivering it to the laboratory without changing its microbiological condition. The reliability of the result depends on this first step: a sample taken incorrectly or contaminated during sampling will not reflect the true condition of the product, however carefully the laboratory works.
Before sampling: plan and materials
Sampling starts with a plan: decide in advance which product, which lot, which point and which analyses. The sample must be representative; taking only the part that looks cleanest or dirtiest will mislead. Agree the required quantity with the laboratory according to the list of analyses. For example, testing for Salmonella is usually done on a 25 g test portion; more sample is needed when several analyses are requested. If the same product is also sampled for chemical or physical testing, take the microbiological sample first and separately.
- Sterile sample bags or sterile screw-cap sample containers
- Sterile spoons, spatulas, knives or forceps; single-use sterile tools where possible
- Disposable gloves and alcohol for disinfecting tools
- Sterile swabs and, if needed, a sterile template for surface samples
- Waterproof marker, labels and a sampling form
- Insulated transport box, cold packs and a thermometer if required
Aseptic sampling step by step
- Prepare: Wash your hands, put on clean gloves and choose a spot with little draught and dust.
- Clean the outside of the package: If a portion is taken from a packed product, wipe the area to be opened with alcohol and let the alcohol evaporate completely; residual alcohol can affect the microorganisms in the sample.
- Open the bag: Tear off the top strip or open the zip; do not touch the inner surface or the mouth of the bag.
- Take the sample: Take material from different points of the product with a sterile tool and transfer it directly into the bag. Use a new sterile tool for each sample or re-sterilise the tool.
- Do not overfill: Leave enough space for the bag to close easily; gently squeeze out excess air.
- Close: Press a zip-lock closure along its full length; fold a wire-closure bag over tightly several times and twist the wires. Screw container caps on fully.
- Label and record: Label the sample immediately, complete the form and place the sample in a transport box at the appropriate condition.
For closed retail packs, sending the product unopened in its original packaging is often preferred where possible, as it removes the risk of contamination during sampling.
Sample bag or sample container?
The choice depends on the physical nature of the sample and how it will be processed in the laboratory.
| Sample type | Suitable container | Why |
|---|---|---|
| Solid, piece or powdered foods (meat, cheese, flour, spices) | Zip-lock sterile sample bag | Wide opening, easy filling, tight closure |
| Liquid and semi-liquid products (milk, sauces, juice) | Stand-up sterile bag or sterile screw-cap container | Stands on its own; low risk of spills and leaks |
| Sample going straight to homogenisation | Filter stomacher bag | The sample can be diluted and homogenised in the same bag |
| Equipment and work surfaces | Sterile swab or swab with neutralising solution | Collects surface microorganisms; neutralises disinfectant residues |
| Sharp, bony or hard products | Double bagging or a rigid sterile container | Reduces the risk of puncture and leakage |
Zip-lock sterile sample bags are practical for solids, while a stand-up sterile sample bag or a sterile sample container suits liquids. If the laboratory will dilute and homogenise the sample directly, a filter stomacher bag removes an extra transfer step. See also the sterile sample bag guide for bag types.
Surface sampling with swabs
The hygiene of surfaces such as equipment, conveyor belts or cutting boards is monitored with swabs; ISO 18593 provides the general framework. The swab tip is moistened with a sterile diluent or neutralising solution, the defined area (e.g. inside a 10×10 cm template) is wiped in perpendicular directions while rotating the swab, and the swab is returned to its tube. On surfaces cleaned with disinfectant, a swab with neutralising solution stops residual disinfectant from continuing to act on microorganisms during transport and prevents falsely low results. For details see the surface hygiene swab guide.
Labelling and records
An unlabelled or poorly labelled sample may be rejected or mismatched in the laboratory. Write the label on the body of the bag or container, not on the closure, using a waterproof marker; condensation in the cold chain can wash off water-soluble ink.
- Unique sample code
- Product name, lot number, production or use-by date
- Place and point of sampling
- Date and time of sampling, name of the sampler
- Product temperature at sampling (if measured)
- Analyses requested
Transport and the cold chain
The aim is to preserve the microbiological condition the sample had when it was taken. General rules:
- Chilled products are kept cold but not frozen; use a separator so that cold packs do not touch the sample directly.
- Frozen products are transported frozen and must not thaw on the way.
- Shelf-stable products (dry foods, sealed cans) can usually travel at ambient conditions, protected from sun and heat.
- Deliver the sample to the laboratory as soon as possible; agree with the laboratory in advance if there will be a delay.
- Transport bags upright inside a second bag; keep the sampling form in a separate dry pocket.
For chlorinated water samples, sterile containers with sodium thiosulfate are used, because residual chlorine can affect bacteria during transport (ISO 19458).
Common mistakes
- Touching the mouth of the bag or the inside of the cap
- Wiping a tool with alcohol and touching the sample before the alcohol evaporates
- Overfilling the bag; leaks from a closure that does not seal
- Putting bony, sharp or hard frozen pieces into a single thin bag
- Freezing a chilled sample by direct contact with a cold pack
- Sticking the label on the cap or using water-soluble ink
- Leaving the sample for a long time in a vehicle or in the sun
In official controls, sampling, sealing and counter-sample rules are set by the applicable legislation. This guide summarises general good practice for in-house checks and routine samples sent to a laboratory.
References and standards
- ISO/TS 17728:2015 — Microbiology of the food chain — Sampling techniques for microbiological analysis of food and feed samples
- ISO 6887-1:2017 — Microbiology of the food chain — Preparation of test samples, initial suspension and decimal dilutions for microbiological examination — Part 1: General rules for the preparation of the initial suspension and decimal dilutions
- ISO 18593:2018 — Microbiology of the food chain — Horizontal methods for surface sampling
- ISO 19458:2006 — Water quality — Sampling for microbiological analysis
The other parts of the ISO 6887 series give sample preparation rules specific to particular product groups.
Questions
Frequently asked questions
How do you use a sterile sample bag?
Tear off the top strip or open the zip and open the bag without touching its mouth. Transfer the sample with a sterile tool and leave enough space to close the bag. Press a zip-lock closure along its full length, or fold a wire-closure bag over several times and twist the wires. Write the label on the body of the bag with a waterproof marker.
How should a food sample be transported to the laboratory?
In an insulated box and according to the product's own storage condition: chilled products cold but not frozen, frozen products frozen, and dry shelf-stable products at ambient conditions protected from the sun. Deliver the sample as soon as possible and agree with the laboratory in advance if there will be a delay.
How much sample is needed for microbiological analysis?
It depends on the analyses requested, so agree it with the laboratory in advance. For example, testing for Salmonella is usually done on a 25 g test portion, and for enumeration the initial dilution is commonly prepared from 10 g of sample in 90 ml of diluent. Increase the quantity if several analyses or repeats are needed.
Should packed products be sent unopened?
Where possible, yes. The unopened original package removes the risk of contamination during sampling and represents the product as sold. If a portion must be taken from a large pack, disinfect the area to be opened, let the alcohol evaporate and transfer the sample with a sterile tool into a sterile bag or container.
How can I obtain sterile sample bags and containers from Diaplas?
You can review Diaplas zip-lock and stand-up sterile sample bags, sample containers and swabs on the product pages. For the products and quantities you need, call us on +90 216 473 80 70 or fill in the quote request form on the website.
Source your sampling supplies from one place
Browse zip-lock and stand-up sterile sample bags, sample containers and swabs, and request a quote for your needs.
